How to install a finned tube cooler

The fresh air system can recover the heat and moisture from indoor exhaust air to treat the fresh air, effectively saving energy. At the same time, the finned cooler fresh air system can filter and purify the outdoor fresh air, ensuring that the air entering the room is fresh and clean.

The fresh air system can recover the heat and moisture from indoor exhaust air to treat the fresh air, effectively saving energy. At the same time, the shell-and-tube cooler fresh air system can filter and purify outdoor fresh air, ensuring that the air entering indoors is fresh and clean. The correct installation of the shell-and-tube cooler greatly affects the use of the shell-and-tube cooler fresh air system. So how should the shell-and-tube cooler be installed? Our company will discuss this issue in detail below:

1. There are requirements for the distance between the fresh air inlet and the return air inlet.

If the fresh air inlet and the return air inlet are too close, it will cause a short circuit between the fresh air and return air, where the exhaust air directly enters the fresh air duct and returns indoors. The fresh air volume will not meet the indoor fresh air requirements, and the fresh air system cannot function properly. Therefore, there must be a certain distance between the fresh air inlet and the exhaust air outlet to avoid short-circuiting between fresh and return air.

2. The indoor placement of the dual cooler requires attention.

The shell-and-tube cooler generates some noise during operation, so it is generally arranged in places where noise requirements are not high, such as kitchens and bathrooms. Additionally, the shell-and-tube cooler needs to connect to the fresh air duct, so enough space must be reserved for pipe connections. Furthermore, during equipment use, problems may arise that require maintenance, so sufficient space must be reserved to allow smooth maintenance.

3. Attention is needed when connecting pipes to the shell-and-tube cooler.

To protect the shell-and-tube cooler, it generally should not be in direct contact with the fresh air duct to avoid the weight of the pipes directly pressing on the cooler and causing damage. The dual cooler usually leaves a certain gap at the connection between the fresh air duct and the main unit, which is filled with tape. At the same time, the direction of the main unit must be confirmed, as well as the air inlet and outlet markings, to prevent the fresh air duct and return air duct from being installed incorrectly.

Latest News


Installation foundation of the heat exchanger

The installation foundation for manufacturing heat exchangers is mainly used for the horizontal installation of the heat exchanger, the connection of pipelines, and the future maintenance of the heat exchanger.


Precautions during routine inspection of the cooler

Mentioning air coolers, they are seen relatively less in our daily lives, but they still have very important uses in some industries or large-scale buildings. There are many things to pay attention to during the regular inspection of coolers. So, what exactly needs to be noted? Please follow the professional technical staff below for an introduction.


Selection of Heat Exchanger Plates

After confirming the heat exchanger area, the plate needs to be selected. Currently, most heat exchanger manufacturers use herringbone corrugated plates.